Controller provides data collection and processing and communication protocols conversion at solving automation tasks.
The controller can be operated as a separate unit and be a part of automatics cabinets and control and alarm panels including those of fire-and-security, monitoring and protection united in a network with upper level equipment with the help of interfaces.
The controller allows solving the following tasks in any combination or simultaneously:
Controller provides data collection and processing and communication protocols conversion at solving automation tasks.
The controller can be operated as a separate unit and be a part of automatics cabinets and control and alarm panels including those of fire-and-security, monitoring and protection united in a network with upper level equipment with the help of interfaces.
The controller allows solving the following tasks in any combination or simultaneously:
The module provides generation and output of discrete signals by commands received via RS-485 interface.
The module is intended to be built in automatics cabinets and control, monitoring and protection panels united in a network with upper level equipment with the help of RS-485 interfaces.
Controller provides control of protected facilities alarm loops with non-addressable security, fire and fire-and-security detectors installed therein.
Controller being a part of set of technical means of fire and security alarm and fire suppression control KTS-2000 is designed for control of protected facilities alarm loops with non-addressable security, fire and fire-and-security detectors installed therein, both when AL (alarm loop) is directly connected to controller and through remote modules via RS-485 interface; for transmission of alarm signals upon actuation of detectors or violation of AL communication line integrity (fault, short circuit) to light and sound alarms through relay outputs and to the mid/upper-level equipment (KTS-2000, PC) via RS-485/Ethernet interfaces; for digital signal control with a solid-state relay; for local and centralized control of protected areas, fire fighting and smoke removal units, voice announcement, control of engineering equipment and light and sound alarms.
The module provides discrete signals input and data output via RS-485 interface.
The module is intended for discrete signals input and data output via RS-485 interface. The module is intended to be built in automatics cabinets and control, monitoring and protection panels united in a network with upper level equipment with the help of RS-485 interface.
The module provides analog signals input and data output via RS-485 interface.
The module is intended for transformation of unified electrical continuous DC voltage or current signals (as per GOST 26.011) into digital coded signals and their transmission to upper control, monitoring, measurement or regulation system via RS-485 interface.
The module provides analog signals output and data receipt via RS-485 interface.
The module is intended for receipt of digital coded signals via RS-485 interface and their transformation into output digital and analog DC signals (solid state relay, current signals from 0 to 20 mA).
The module is intended for operation as part of design-specific distributed fire and security alarm systems and shall be mounted on structural elements (cabinet, floor panel) of KTS-2000, KTS SA.
The module can be restored and repaired, it is intended for day-and-night continuous operation.
The module provides 220 V discrete signals input and data output via RS-485 interface.
The module is intended for 220 V discrete signals input and data output via RS-485 interface.
The module is intended to be built in automatics cabinets and control, alarm, monitoring and protection panels united in a network with upper level equipment with the help of RS-485 interface.
The module provides control of alarm loops with installed in them non-addressable security, fire and fire and security detectors.
The module is designed to control alarm loops non-addressable security, fire and fire and security detectors and process parameters sensors of fire suppression systems installed therein (with output signals of "dry contact" type), for remote AL restart, transmission of AL status (detector actuation, violation of AL communication line integrity (break, short circuit)) to mid level equipment of KTS-2000 via RS-485 interface with Modbus RTU protocol.
Required for power supply, control and regulation of addressable fire detectors.
This module is a part of Fire and Security Alarm Hardware and Software System KTS-2000 (TU4371-006-12221545-01) and is intended for power supply, control and regulation of addressable fire detectors (AFD) using XP95 protocol (“Apollo Fire Detectors Ltd”). AFD is connected with the help of two-wire addressable loop on both sides, that is the loop is circuited, that facilitates the system reliability. Up to 126 addressable devices can be connected to this circular addressable loop.